A novel technique was developed to measure the tendon load in people and in horses in motion. This
non-invasive technique is based on a relation, demonstrated experimentally in vitro on isolated tendons
and limbs, between the velocity of ultrasound in the tendon and the load to which it is subjected.
A prototype was created to examine the equine superficial digital flexor tendon. The reproducibility
of these measurements assessed in five horses was very good in a given subject, but marked
differences were observed between the animals, in terms of plot shape and ultrasound velocity. These
differences appeared directly related to the horse’s digital standing conformation. The technique thus
validated was then used to examine the effect of four types of orthopaedic shoes compared to a standard
shoe, on hard as well as soft ground.Un procédé original de mesure
de la force qui s'exerce dans un tendon, chez le Cheval ou l'Homme en mouvement, a été mis
au point. Cette technique non-invasive repose sur une relation, démontrée expérimentalement
in vitro, sur tendons et membres isolés, entre la vitesse des ultrasons dans un tendon et la
force qui s'applique sur celui-ci. Un prototype adapté au tendon fléchisseur superficiel du
doigt du cheval a été réalisé. La reproductibilité des mesures, évaluée chez cinq chevaux,
au pas et au trot, est très bonne chez un même individu, mais il existe des différences
nettes entre sujets, à la fois dans la forme des tracés et dans les niveaux de vitesse des
ultrasons observés. Ces différences sont apparues étroitement liées à l'aplomb digital des
chevaux. Le procédé ainsi validé a permis d'évaluer l'effet de quatre types de ferrures
correctrices, comparées à un fer standard, sur sol dur et sur sol meuble