The development and optimization of a sequential injection analysis (SIA) flow system is presented for the
determination of zinc in milk powder and infant formulae. The determination is based on the reaction of Zn(II)
with zincon at pH 9 in the presence of sodium citrate to mask the interfering matrix with spectrophotometric
detection at 612 nm. The system was optimized by multivariate experiments. The validated system presented a
linear range from 0.4 to 10 mg L-1 and the precision of the method was better than 5% (sr(%), n = 10). The
detection limit was 0.13 mg L-1. The results obtained using the proposed and reference methods were found to
be statistically equivalent. The sampling frequency was 75 samples per hour and the sample and reagent
consumption of 0.24 mL per determination. The proposed method was accurate, simple, fast and according to
the principles of green chemistry generating just 0.24 mL of chemical waste.Se presenta el desarrollo y optimización de un sistema en flujo con inyección secuencial (SIA) para la
determinación de zinc en leche en polvo y fórmulas infantiles. La determinación se basa en la reacción de Zn(II)
con zincón a pH 9 en presencia de citrato de sodio para enmascarar interferentes de la matriz con detección
espectrofotométrica a 612 nm. El sistema fue optimizado mediante experimentos multivariantes. El sistema
validado presentó un rango lineal de 0.4 a 10 mg L-1, la precisión del método fue mejor que 5% (sr,%; n=10). El
límite de detección fue 0.13 mg L-1. Los resultados obtenidos utilizando el método propuesto y el de referencia
fueron estadísticamente equivalentes. La frecuencia de muestreo fue de 75 muestras/hora y el consumo de
muestra y reactivo 0.24 mL por determinación. El método propuesto resultó veraz, simple, rápido y está de
acuerdo a los principios de la química verde, generando apenas 0.24 mL de residuos químicos