CORE
🇺🇦
make metadata, not war
Services
Research
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Effect of electronic cigarette (EC) aerosols on particle size distribution in indoor air and in a radon chamber
Authors
H. N. Khalaf
M. Y. A. Mostafa
M. Zhukovsky
Publication date
1 January 2019
Publisher
'Walter de Gruyter GmbH'
Doi
Abstract
Particle size distribution is an important factor governing whether aerosols can be deposited in various respiratory tract regions in humans. Recently, electronic cigarette (EC), as the alternative of tobacco cigarette, has become increasingly popular all over the world. However, emissions from ECs may contribute to both indoor and outdoor air pollution; moreover, comments about their safety remain controversial, and the number of users is increasing rapidly. In this investigation, aerosols were generated from ECs and studied in the indoor air and in a chamber under controlled conditions of radon concentration. The generated aerosols were characterized in terms of particle number concentrations, size, and activity distributions by using aerosol diffusion spectrometer (ADS), diffusion battery, and cascade impactor. The range of ADS assessment was from 10 -3 μm to 10 μm. The number concentration of the injected aerosol particles was between 40 000 and 100 000 particles/cm 3 . The distribution of these particles was the most within the ultrafi ne particle size range (0-0.2 μm), and the other particle were in the size range from 0.3 μm to 1 μm. The surface area distribution and the mass size distribution are presented and compared with bimodal distribution. In the radon chamber, all distributions were clearly bimodal, as the free radon decay product was approximately 1 nm in diameter, with a fraction of ~0.7 for a clean chamber (without any additional source of aerosols). The attached fraction with the aerosol particles from the ECs had a size not exceeding 1.0 μm. © 2019 H. N. Khalaf, M. Y. A. Mostafa & M. Zhukovsky
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Institutional repository of Ural Federal University named after the first President of Russia B.N.Yeltsin
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:elar.urfu.ru:10995/73991
Last time updated on 10/07/2019