Response of EBR-II to a complete loss of primary forced flow during power operation

Abstract

Detailed measurements of the thermal, hydraulic, and neutronic response of EBR-II to a complete loss of primary forced flow followed by a PPS-activated scram are presented. The experimental results clearly indicate a smooth transition to natural convective flow with a quite modest incore temperature transient. The accompanying calculations using the NATDEMO code agree quite well with the measured temperatures and flow rates throughout the primary system. The only region of the plant where a significant discrepancy between the measurements and calculations occurred was in the IHX. The reasons for this result could not be definitively determined, but it is speculated that the one-dimensional assumptions used in the modeling may not be valid in the IHX during buoyancy driver flows