The program objectives were to (1) assess the feasibility of using the TRNSYS computer code for solar heating and cooling control studies and modify it wherever possible, and (2) develop a new dynamic model of the solar collector which reflects the performance of the collector under transient conditions. Also, the sensitivity of the performance of this model to the various system parameters such as collector time constants, flow rates, turn-on and turn-off temperature set points, solar insolation, etc., was studied. Results are presented and discussed. (WHK