Respirator studies for the Nuclear Regulatory Commission. Evaluation and performance of escape-type self-contained breathing apparatus. Progress report, October 1, 1978-September 30, 1979

Abstract

The performance of escape type breathing apparatus was evaluated for weight, comfort, ease of use, and protection factor (calculated from facepiece leakage). All of the devices tested provided a self-contained air supply of 5- to 15-min duration. Five of them have the provision to connect an air line but allow the use of the self-contained supply for safe egress. The air supply was stored in cylinders, tubing, or disposable containers. Respiratory inlet coverings were half masks, full facepieces, hoods, and mouthpieces. An estimate is given for the ease of quick donning. Recommendations for conditions of use of the equipment are given. 8 refs., 10 figs., 3 tabs