Electrochemical Safety Studies of Cochlear Implant Electrodes Using the Finite Element Method

Abstract

Cochlear implants, amongst other neural prostheses, utilise platinum electrodes as an interface between the synthetic implant and the biological tissue environment. If excessive electrical charge is injected via these electrodes, injury to the tissue may result. Empirically derived stimulation limits have been defined to prevent tissue damage, however the injurious mechanisms are still unclear. Evidence suggests that the non-uniform distribution of charge on electrodes influences the electrochemical generation of toxic by-products. However, in vivo and in vitro techniques are limited in their ability to systematically explore the factors and mechanisms that contribute to stimulation-induced tissue injury. To this end, an in silico approach was used to develop a time-domain model of cochlear implant stimulation electrodes. A constant phase angle impedance was used to model the reversible processes on the electrode surface, and Butler-Volmer reaction kinetics were used to define the behaviour of the water window irreversible electrochemical reactions. The resulting model provided time-domain responses of the current density distributions, and net charge consumed by the hydrolysis reactions. This model was then used to perform systematic evaluations of various electrode geometries and stimulation parameters. The modelling results showed the current associated with irreversible reactions was non-uniform and tended towards the periphery of the electrode. A comparison of electrode geometries revealed interactions between electrode size, shape and recess depth. Stimulation mode, electrode position, and electrolyte conductivity were found to impact the shape of the electric field and the extent of irreversible reactions. This emphasised the influence of the physiological environment on the stimulation safety. In vitro experiments were conducted to validate the model. The implications of the results described in this thesis can be used to inform the design of safer electrodes

    Similar works