International Telemetering Conference Proceedings / October 17-20, 1988 / Riviera Hotel, Las Vegas, NevadaA switched-capacitor technique for realization of one bit serial A/D converter is presented. A conversion accuracy that is higher than 15 bits can be expected from its integrated realization. Results of simulation are presented. It is shown that arithmetic operations on bit serial signals are possible. Using arithmetic operations on delta-modulated signals, it is possible to build inexpensive options necessary in instrumentation.International Foundation for TelemeteringProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection