CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Fast scanning calorimetry of lysozyme unfolding at scanning rates from 5 K/min to 500,000 K/min
Authors
Mukhametzyanov T.
Schick C.
Sedov I.
Solomonov B.
Publication date
1 January 2018
Publisher
Abstract
© 2018 Elsevier B.V. Background: Protein denaturation is often studied using differential scanning calorimetry (DSC). However, conventional instruments are limited in the temperature scanning rate available. Fast scanning calorimetry (FSC) provides an ability to study processes at much higher rates while using extremely small sample masses [ng]. This makes it a very interesting technique for protein investigation. Methods: A combination of conventional DSC and fast scanning calorimeters was used to study denaturation of lysozyme dissolved in glycerol. Glycerol was chosen as a solvent to prevent evaporation from the micro-sized samples of the fast scanning calorimeter. Results: The lysozyme denaturation temperatures in the range of scanning rates from 5 K/min to ca. 500,000 K/min follow the Arrhenius law. The experimental results for FSC and conventional DSC fall into two distinct clusters in a Kissinger plot, which are well approximated by two parallel straight lines. Conclusions: The transition temperatures for the unfolding process measured on fast scanning calorimetry sensor are significantly lower than what could be expected from the results of conventional DSC using extrapolation to high scanning rates. Evidence for the influence of the relative surface area on the unfolding temperature was found. General significance: For the first time, fast scanning calorimetry was employed to study protein denaturation with a range of temperature scanning rates of 5 orders of magnitude. Decreased thermal stability of the micro-sized samples on the fast scanning calorimeter raise caution over using bulk solution thermal stability data of proteins for applications where micro-sized dispersed protein solutions are used, e.g., spray drying
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Kazan Federal University Digital Repository
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:dspace.kpfu.ru:net/147982
Last time updated on 07/05/2019