Noise simulation system for determining imaging conditions in digital radiography
Authors
Ichikawa Katsuhiro
Kawashima Hiroki
Matsubara Kosuke
Tanaka Rie
Publication date
8 February 2012
Publisher
'SPIE-Intl Soc Optical Eng'
Doi
Cite
Abstract
Reduction of exposure dose and improvement in image quality can be expected to result from advances in the performance of imaging detectors. We propose a computerized method for determining optimized imaging conditions by use of simulated images. This study was performed to develop a prototype system for image noise and to ensure consistency between the resulting images and actual images. An RQA5 X-ray spectrum was used for determination of input-output characteristics of a flat-panel detector (FPD). The number of incident quantum to the detector per pixel (counts/pixel) was calculated according to the pixel size of the detector and the quantum number in RQA5 determined in IEC6220-1. The relationship among tube current-time product (mAs), exposure dose (C/kg) at the detector surface, the number of incident quanta (counts/pixel), and pixel values measured on the images was addressed, and a conversion function was then created. The images obtained by the FPD was converted into a map of incident quantum numbers and input into random-value generator to simulate image noise. In addition, graphic user interface was developed to observe images with changing image noise and exposure dose levels, which have trade-off relationship. Simulation images provided at different noise levels were compared with actual images obtained by the FPD system. The results indicated that image noise was simulated properly both in objective and subjective evaluation. The present system could allow us to determine necessary dose from image quality and also to estimate image quality from any exposure dose. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE)
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Kanazawa University Repository for Academic Resources
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:kanazawa-u.repo.nii.ac.jp:...
Last time updated on 06/05/2019
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1117%2F12.909838
Last time updated on 05/06/2019