Industrial Research of Condensing Unit for Natural Gas Boiler House
- Publication date
- Publisher
- RTU
Abstract
In the course of work industrial research was
carried out at the boiler plant A/S “Imanta” where a 10MW
passive condensing economizer working on natural gas was
installed after the 116MW water boiler. The work describes
the design of the condensing economizer and wiring diagram.
During the industrial experiment, the following measurements
were made: the temperature of water before and after the
economizer; the ambient temperature; the quantity of water
passing through the economizer; heat, produced by the
economizer and water boilers. The work summarizes the data
from 2010-2011