Multipole radio-frequency traps are central to collisional experiments in
cryogenic environments. They also offer possibilities to generate new type of
ion crystals topologies and in particular the potential to create infinite
1D/2D structures: ion rings and ion tubes. However, multipole traps have also
been shown to be very sensitive to geometrical misalignment of the trap rods,
leading to additional local trapping minima. The present work proposes a method
to correct non-ideal potentials, by modifying the applied radio-frequency
amplitudes for each trap rod. This approach is discussed for the octupole trap,
leading to the restitution of the ideal Mexican-Hat-like pseudo-potential,
expected in multipole traps. The goodness of the compensation method is
quantified in terms of the choice of the diagnosis area, the residual trapping
potential variations, the required adaptation of the applied radio-frequency
voltage amplitudes, and the impact on the trapped ion structures. Experimental
implementation for macroscopic multipole traps is also discussed, in order to
propose a diagnostic method with respect to the resolution and stability of the
trap drive. Using the proposed compensation technique, we discuss the
feasibility of generating a homogeneous ion ring crystal, which is a measure of
quality for the obtained potential well