As primary provider for research computing services at the University of
Minnesota, the Minnesota Supercomputing Institute (MSI) has long been
responsible for serving the needs of a user-base numbering in the thousands.
In recent years, MSI---like many other HPC centers---has observed a growing
need for self-service, on-demand, data-intensive research, as well as the
emergence of many new controlled-access datasets for research purposes. In
light of this, MSI constructed a new on-premise cloud service, named Stratus,
which is architected from the ground up to easily satisfy data-use agreements
and fill four gaps left by traditional HPC. The resulting OpenStack cloud,
constructed from HPC-specific compute nodes and backed by Ceph storage, is
designed to fully comply with controls set forth by the NIH Genomic Data
Sharing Policy.
Herein, we present twelve lessons learned during the ambitious sprint to take
Stratus from inception and into production in less than 18 months. Important,
and often overlooked, components of this timeline included the development of
new leadership roles, staff and user training, and user support documentation.
Along the way, the lessons learned extended well beyond the technical
challenges often associated with acquiring, configuring, and maintaining
large-scale systems.Comment: 8 pages, 5 figures, PEARC '18: Practice and Experience in Advanced
Research Computing, July 22--26, 2018, Pittsburgh, PA, US