CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Entwicklung einer hochauflösenden Kamera für die Mikroskopie mit harter Röntgenstrahlung
Authors
Jens Patommel
Publication date
17 November 2003
Publisher
Abstract
Seit mit den Synchrotronstrahlungsquellen dritter Generation hochbrillante Röntgenquellen zur Verfügung stehen, haben sich Vollfeldmikroskopie und Rastersondenmikroskopie mit harter Röntgenstrahlung als besonders nützliche Untersuchungsmethoden etabliert. Insbesondere bei der vergrößernden Mikroskopie mit harter Röntgenstrahlung werden Röntgenkameras mit hoher Anforderung bezüglich der Ortsauflösung benötigt. Im Rahmen dieser Diplomarbeit wurde ein zweidimensionaler Röntgendetektor für die Mikroskopie mit harter Röntgenstrahlung entworfen, gebaut und im Experiment getestet und charakterisiert. Hauptaugenmerk war dabei ein möglichst hohes Ortsauflösungsvermögen des Detektors verbunden mit einem großen effektiven dynamischen Bereich. Als vielversprechendes Konzept erwies sich dabei die Verwendung eines einkristallinen Szintillators, der mittels einer Mikroskopoptik auf einen CCD-Chip abgebildet wird. Im Experiment stellte sich heraus, dass der im Zuge dieser Diplomarbeit konzipierte Flächendetektor sämtliche an ihn gestellten Anforderungen hervorragend erfüllt. Obwohl ursprünglich für die vergrößernde Tomographie mit harter Röntgenstrahlung entwickelt, findet die Röntgenkamera darüber hinaus beim Justieren nanofokussierender refraktiver Röntgenlinsen in Rastersondenmikroskopen Verwendung.:1 Einleitung . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Das Erzeugen von Röntgenstrahlung . . . . . . . . . . . . 3 2.1 Röntgenröhren . . . . . . . . . . . . . . . . . . . . . 3 2.2 Synchrotronstrahlung . . . . . . . . . . . . . . . . . . 6 2.3 Sonstige Röntgenquellen . . . . . . . . . . . . . . . . 10 3 Röntgendetektoren . . . . . . . . . . . . . . . . . . . . 11 3.1 Gasionisationsdetektoren . . . . . . . . . . . . . . . . 11 3.2 Halbleiterdetektoren . . . . . . . . . . . . . . . . . . 13 3.3 Szintillationsdetektoren . . . . . . . . . . . . . . . . 16 3.4 Röntgenfilme . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Bildplatten . . . . . . . . . . . . . . . . . . . . . . 18 3.6 CCD-Detektoren . . . . . . . . . . . . . . . . . . . . . 20 3.6.1 Funktionsweise eines CCD-Chips . . . . . . . . . . . . 20 3.6.2 Direkte CCD-Detektoren . . . . . . . . . . . . . . . . 24 3.6.3 CCD-Detektoren mit Faseroptiken . . . . . . . . . . . 25 3.6.4 CCD-Detektoren mit Linsenoptiken . . . . . . . . . . . 26 4 Abbilden mit Röntgenstrahlung . . . . . . . . . . . . . . 29 4.1 Transmission von Röntgenstrahlung durch eine Probe . . . 30 4.2 Detektormittelwert . . . . . . . . . . . . . . . . . . . 34 4.3 Absorptionskontrast . . . . . .. . . . . . . . . . . . . 35 4.4 Beugung und Propagation . . . . . . . . . . . . . . . . 36 4.5 Korrelation und wechselseitige Intensität . . . . . . . 38 4.6 Das Theorem von Van Cittert und Zernike . . . . . . . . 41 4.7 Projektionsabbildung . . . . . . . . . . . . . . . . . . 42 4.8 Das Röntgenmikroskop . . . . . . . . . . . . . . . . . . 43 5 Hochauflösende Röntgenkamera . . . . . . . . . . . . . . . 45 5.1 Anforderungen an den Detektor . . . . . . . . . . . . . 45 5.2 Szintillator . . . . . . . . . . . . . . . . . . . . . . 46 5.3 Mikroskop . . . . . . . . . . . . . . . . . . . . . . . 53 5.4 CCD-Kamera . . . . . . . . . . . . . . . . . . . . . . . 55 6 Charakterisierung des Detektors . . . . . . . . . . . . . 61 6.1 Versuchsaufbau . . . . . . . . . . . . . . . . . . . . . 61 6.2 Auswertung . . . . . . . . . . . . . . . . . . . . . . . 63 6.3 Nickel-Gitter . . . . . . . . . . . . . . . . . . . . . 64 6.4 Goldstreifen . . . . . . . . . . . . . . . . . . . . . . 71 6.5 Mikroprozessor . . . . . . . . . . . . . . . . . . . . . 75 6.6 Einfluss der Quellgröße . . . . . . . . . . . . . . . . . 79 7 Zusammenfassung und Ausblick . . . . . . . . . . . . . . . 81 Literaturverzeichnis . . . . . . . . . . . . . . . . . . . . 85 Abbildungsverzeichnis . . . . . . . . . . . . . . . . . . . 89 Tabellenverzeichnis . . . . . . . . . . . . . . . . . . . . 91 Danksagung . . . . . . . . . . . . . . . . . . . . . . . . . 93With the advent of highly-brilliant third generation synchrotron radiation sources, hard x-ray full-field microscopy and hard x-ray scanning microscopy were developed and have been shown to be excellent methods for scientific investigations. Especially for magnified hard x-ray full-field microscopy, there is the need for two-dimensional x-ray detectors with highest demands on spatial resolution and effective dynamic range. In the course of this diploma thesis, such an area x-ray detector with high spatial resolution and large dynamic range was designed and built and then tested and characterized in experiment. The high-resolution x-ray camera consists of a visible light microscope which images the sensitive layer of a single-crystal scintillator on the CCD chip of a CCD camera. A test experiment gave evidence that the x-ray camera actually fulfills all the requirements with regard to spatial resolution, sensitivity and effective dynamic range. Originally, the detector was developed for magnified hard x-ray tomography, but in addition, it is applied for alignment purposes of nanofocusing refractive x-ray lenses in a hard x-ray scanning microscope.:1 Einleitung . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Das Erzeugen von Röntgenstrahlung . . . . . . . . . . . . 3 2.1 Röntgenröhren . . . . . . . . . . . . . . . . . . . . . 3 2.2 Synchrotronstrahlung . . . . . . . . . . . . . . . . . . 6 2.3 Sonstige Röntgenquellen . . . . . . . . . . . . . . . . 10 3 Röntgendetektoren . . . . . . . . . . . . . . . . . . . . 11 3.1 Gasionisationsdetektoren . . . . . . . . . . . . . . . . 11 3.2 Halbleiterdetektoren . . . . . . . . . . . . . . . . . . 13 3.3 Szintillationsdetektoren . . . . . . . . . . . . . . . . 16 3.4 Röntgenfilme . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Bildplatten . . . . . . . . . . . . . . . . . . . . . . 18 3.6 CCD-Detektoren . . . . . . . . . . . . . . . . . . . . . 20 3.6.1 Funktionsweise eines CCD-Chips . . . . . . . . . . . . 20 3.6.2 Direkte CCD-Detektoren . . . . . . . . . . . . . . . . 24 3.6.3 CCD-Detektoren mit Faseroptiken . . . . . . . . . . . 25 3.6.4 CCD-Detektoren mit Linsenoptiken . . . . . . . . . . . 26 4 Abbilden mit Röntgenstrahlung . . . . . . . . . . . . . . 29 4.1 Transmission von Röntgenstrahlung durch eine Probe . . . 30 4.2 Detektormittelwert . . . . . . . . . . . . . . . . . . . 34 4.3 Absorptionskontrast . . . . . .. . . . . . . . . . . . . 35 4.4 Beugung und Propagation . . . . . . . . . . . . . . . . 36 4.5 Korrelation und wechselseitige Intensität . . . . . . . 38 4.6 Das Theorem von Van Cittert und Zernike . . . . . . . . 41 4.7 Projektionsabbildung . . . . . . . . . . . . . . . . . . 42 4.8 Das Röntgenmikroskop . . . . . . . . . . . . . . . . . . 43 5 Hochauflösende Röntgenkamera . . . . . . . . . . . . . . . 45 5.1 Anforderungen an den Detektor . . . . . . . . . . . . . 45 5.2 Szintillator . . . . . . . . . . . . . . . . . . . . . . 46 5.3 Mikroskop . . . . . . . . . . . . . . . . . . . . . . . 53 5.4 CCD-Kamera . . . . . . . . . . . . . . . . . . . . . . . 55 6 Charakterisierung des Detektors . . . . . . . . . . . . . 61 6.1 Versuchsaufbau . . . . . . . . . . . . . . . . . . . . . 61 6.2 Auswertung . . . . . . . . . . . . . . . . . . . . . . . 63 6.3 Nickel-Gitter . . . . . . . . . . . . . . . . . . . . . 64 6.4 Goldstreifen . . . . . . . . . . . . . . . . . . . . . . 71 6.5 Mikroprozessor . . . . . . . . . . . . . . . . . . . . . 75 6.6 Einfluss der Quellgröße . . . . . . . . . . . . . . . . . 79 7 Zusammenfassung und Ausblick . . . . . . . . . . . . . . . 81 Literaturverzeichnis . . . . . . . . . . . . . . . . . . . . 85 Abbildungsverzeichnis . . . . . . . . . . . . . . . . . . . 89 Tabellenverzeichnis . . . . . . . . . . . . . . . . . . . . 91 Danksagung . . . . . . . . . . . . . . . . . . . . . . . . . 9
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
HSSS - Hochschulschriftenserver der SLUB
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:qucosa:de:qucosa:985
Last time updated on 05/11/2018
Qucosa
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:qucosa:de:qucosa:985
Last time updated on 23/08/2018
Sächsische Landesbibliothek - Staats- und Universitätsbibliothek Dresden (SLUB): Qucosa
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:qucosa:de:qucosa:985
Last time updated on 15/12/2019