research

On the testing of large PV arrays

Abstract

This paper reports on the IES-UPM experience from 2006 to 2010 in the field of the characterization of PV arrays of commercial large PV plants installed in Spain within the framework of the profitable economic scenarios associated to feed-in tariff laws. This experience has extended to 200 MW and has provided valuable lessons to minimize uncertainty, which plays a key role in quality assurance procedures. The paper deals not only with classic I–V measurements but also with watt-metering-based procedures. Particular attention is paid to the selection of irradiance and cell temperature sensor

    Similar works