One‐year mortality associated with COPD treatment: a comparison of tiotropium and long‐acting beta2‐agonists in three Italian regions: results from the OUTPUL study
Authors
Nera Agabiti
Lisa Bauleo
+8 more
Silvia Cascini
Marina Davoli
Mirko Di Martino
Giulio Formoso
Ursula Kirchmayer
Elisabetta Patorno
Riccardo Pistelli
Claudio Voci
Publication date
2 December 2016
Publisher
'Wiley'
Doi
Abstract
Abstract Purpose Long‐acting bronchodilators, i.e. beta‐2‐agonists (LABA) and tiotropium are commonly used in COPD treatment. Choice of a specific agent is based on effectiveness and safety. Evidence yields controversial results with respect to mortality. The present study compared one‐year mortality associated to treatment with tiotropium versus LABA. Methods: A population‐based cohort study using data from Italian health information systems was performed. Patients aged 45+ years, discharged with COPD diagnosis in 2006–2009 were identified. Through record linkage with drug claims, patients who received a first prescription of LABA or tiotropium within 6 months after discharge were enrolled. The main analysis was restricted to naïve users (no prior use of either LABA or tiotropium). We used ‘intention to treat’ (ITT) and ‘as treated’ (AT) approaches. We followed patients for a maximum of 12 months. Hazard ratios (HRs) were calculated by Cox regression including quintiles of propensity score. In sensitivity analysis patients receiving tiotropium + LABA combination were included in the tiotropium group. Results: Among the 33 891 enrolees, 28% were exposed to Tio, 56% to LABA, 16% to both. Overall mean age was 74 years and the mortality rate was 122/1000 person‐years (py) at the ITT analysis and 108/1000 py at the AT analysis. The adjusted HR for tiotropium only compared with LABA only was 1.06 (95%CI: 0.94–1.20) at the ITT analysis and 1.00 (95%CI: 0.93–1.08) at the AT analysis. Results were robust in sensitivity analysis. Conclusions: In this real‐world study use of tiotropium was not associated with an increased risk of one‐year mortality compared with LABA. © 2016 The Authors. Pharmacoepidemiology and Drug Safety published by John Wiley & Sons, Ltd
Similar works
Full text
Available Versions
Sustaining member
Harvard University - DASH
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:dash.harvard.edu:1/2962608...
Last time updated on 17/04/2018