RANCANG BANGUN DAN UJI UNJUK KERJA
POMPA GEAR PADA SUHU FLUIDA 70
0
C
(REDESIGN AND PERFOMANCE TEST FOR GEAR PUMP AT 70
DEGREES CELCIUS OF FLUIDS TEMPERATURE)
The purpose of this research is cognizant of characteristic, transfer of fluid, and
performance by operated Gear Pump. Material worked is ex lubricant which 77,905 cP
viscosity then heated from atmospheric to 70
0
C by used heater and temperature of
lubricant is guarded on 70
0
C by used thermostat. Valve are opened on 90 stroke and
frequency inverter operated on 32 Hz up to 50 Hz take a rest 3 Hz. Variable for this
research are frequency motor and stroke of valve. Circling (electric motor and
pump),capacity (input and output), pressure (input and output), temperature (input and
output) are analyzed every three minutes. The results for this research were: 1) Head
optimum of pump system was 21,83 m height at 45 stroked valve and 50 Hz frequency. 2)
Relative Volumetric Performance was taken a 61,05 % great at 90 stroked valve and 32
Hz frequency. 3) Relative Mechanic Performance was taken a 32,07 % great at 90 stroked
valve and 50 Hz frequency. This research has been conclusion that circling, capacity, and
pressure of each valve stroked as greater as developing of frequency, and type of this flow
is laminar.
keywords: Gear pump, frequency, stroke, head, performanc