Myocardial segment-specific model generation for simulating the electrical action of the heart-1

Abstract

<p><b>Copyright information:</b></p><p>Taken from "Myocardial segment-specific model generation for simulating the electrical action of the heart"</p><p>http://www.biomedical-engineering-online.com/content/6/1/21</p><p>BioMedical Engineering OnLine 2007;6():21-21.</p><p>Published online 5 Jun 2007</p><p>PMCID:PMC1896167.</p><p></p> () generated by focal current application at the tissue centres are shown in the . Activation time () fields derived from wavefront propagation from the site of current injection are shown in the . The epi (epicardium) to endo (endocardium) distance is ~17 mm for both models

    Similar works

    Full text

    thumbnail-image

    Available Versions