Design and operation of a protection system for transformers with superconducting windings

Abstract

Power transformers with superconducting windings need a protection system to prevent damage to the low-loss superconducting winding by an abnormally high current. The generally accepted protection technique which uses auxiliary coils has been analysed using a network representation. The current distribution between main and auxiliary coil is expressed in terms of geometrical parameters. Experimental data on current transfer and main coil recovery in a test transformer are presented and a method of obtaining a very low auxiliary coil current is suggested

    Similar works