Abstract

Accurate intima-media thickness (IMT) measurement of the carotid artery from minimal plaque ultrasound images is a relevant clinical need, since IMT increase is related to the progression of atherosclerosis. In this paper, we describe a novel dual snake-based model for the high-performance carotid IMT measurement, called Carotid Measurement Using Dual Snakes (CMUDS). Snakes (which are deformable contours) adapt to the lumen-intima (LI) and media-adventitia (MA) interfaces, thus enabling the IMT computation as distance between the LI and MA snakes. However, traditional snakes might be unable to maintain a correct distance and in some spatial location along the artery, it might even collapse between them or diverge. The technical improvement of this work is the definition of a dual snake-based constrained system, which prevents the LI and MA snakes from collapsing or bleeding, thus optimizing the IMT estimation. The CMUDS system consists of two parametric models automatically initialized using the far adventitia border which we automatically traced by using a previously developed multi-resolution approach. The dual snakes evolve simultaneously and are constrained by the distances between them, ensuring the regularization of LI/MA topology. We benchmarked our automated CMUDS with the previous conventional semi-automated snake system called Carotid Measurement Using Single Snake (CMUSS). Two independent readers manually traced the LIMA boundaries of a multi-institutional, multi-ethnic, and multi-scanner database of 665 CCA longitudinal 2D images. We evaluated our system performance by comparing it with the gold standard as traced by clinical readers. CMUDS and CMUSS correctly processed 100% of the 665 images. Comparing the performance with respect to the two readers, our automatically measured IMT was on average very close to that of the two readers (IMT measurement biases for CMUSS was equal to −0.011 ± 0.329 mm and −0.045 ± 0.317 mm, respectively, while for CMUDS, it was 0.030 ± 0.284 mm and −0.004 ± 0.273 mm, respectively). The Figure-of-Merit of the system was 98.5% and 94.4% for CMUSS, while 96.0% and 99.6% for CMUDS, respectively. Results showed that the dual-snake system CMUDS reduced the IMT measurement error accuracy (Wilcoxon, p < 0.02) and the IMT error variability (Fisher, p < 3 × 10−2). We propose the CMUDS technique for use in large multi-centric studies, where the need for a standard, accurate, and automated IMT measurement technique is require

    Similar works