An accurate measurement method to extract the common mode (CM) and the differential mode (DM) noise source impedances of a switched mode power supply (SMPS) under its operating condition is developed and validated. With a proper pre-measurement calibration process, the proposed method allows extraction of both the CM and the DM noise source impedances with very good accuracy. These noise source impedances come in handy to design an electromagnetic interference (EMI) filter for a SMPS systematically with minimum hassl