CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
research
A Comparison of Calculated and Measured Indoor-Side Window Temperature Profiles
Authors
Alexander G. McGowan
John L. Wright
Publication date
1 January 2003
Publisher
American Society of Heating, Refrigerating and Air-Conditioning Engineers
Abstract
© 2003. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol. 109, Part 2. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission.Computer-generated surface temperature profiles are presented for the indoor side, vertical centerline of two windows and a calibration transfer standard (CTS). These specific configurations were chosen because they match test specimens used in a previous test program, and the resulting temperature profiles, measured using a thermographic camera, are available in the literature. Calculations were completed using the VISION4 program for one-dimensional center-glass analysis and the FRAME 4.0 program for two-dimensional analysis of the edge-glass and frame. Three different computational models were used: (1) the conventional procedure used widely to generate total-window solar gain and heat loss coefficients, (2) a procedure to account for fill-gas motion was added, and (3) the convective heat transfer coefficients were reduced near the recessed corners of the indoor surface. Profiles were scrutinized most closely at the bottom edge-glass section-where condensation most readily occurs. Simulation provides useful qualitative information, and each of the two features added to the model provides better agreement with measurement. It is concluded that simple, inexpensive, and easy-to-use computer software can offer reliable design guidance and performance verification regarding condensation resistance.Natural Sciences and Engineering Research Council of Canad
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
University of Waterloo's Institutional Repository
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:uwspace.uwaterloo.ca:10012...
Last time updated on 01/01/2018