We study the inference of the origin and the pattern of contamination in
water distribution networks. We assume a simplified model for the dyanmics of
the contamination spread inside a water distribution network, and assume that
at some random location a sensor detects the presence of contaminants. We
transform the source location problem into an optimization problem by
considering discrete times and a binary contaminated/not contaminated state for
the nodes of the network. The resulting problem is solved by Mixed Integer
Linear Programming. We test our results on random networks as well as in the
Modena city network