research

Study of critical defects in ablative heat shield systems for the space shuttle

Abstract

Results are presented from an investigation to determine the effects of fabrication-induced defects on the performance of an ablative heat shield material in a simulated space shuttle reentry environment. Nondestructive methods for detecting the defects were investigated. The material considered is a fiber-filled, honeycomb-reinforced, low-density elastomer. Results were obtained for density variations, voids, fiber bundles, crushed honeycomb, undercut honeycomb, unbonded areas, face sheet delaminations, and cure variations. The data indicate that, within reasonable tolerances, the fabrication defects investigated are not critical in terms of reentry performance of the heat shield

    Similar works