Demonstration of the range over which the Langley Research Center digital computer charring ablation program (CHAP) can be used with confidence: Comparisons of CHAP predictions and test data for three ablation materials

Abstract

Comparisons of ablation calculations with the charring ablation computer code and ablation test data are presented over a wide range of environmental conditions in air for three materials: low-density nylon phenolic, Avcoat 5026-39HC/G, and a filled silicon elastomer. Heat fluxes considered range from over 500 Btu/sq ft-sec to less than 50 Btu/sq ft-sec. Pressures range from 0.5 atm to .004 atm. Enthalpies range from about 2000 Btu/lb to 18000 Btu/lb. Predictions of recession, pyrolysis penetration, and thermocouple responses are considered. Recession predictions for nylon phenolic are good as steady state is approached, but strongly transient cases are underpredicted. Pyrolysis penetrations and thermocouple responses are very well predicted. Recession amounts for Avcoat and silicone elastomer are less well predicted, although high heat flux cases near steady state are fairly satisfactory. Pyrolysis penetrations and thermocouple responses are very well predicted