thesis

Static source locations for four nozzles mounted on a J-85 engine

Abstract

The test nozzles included a round 17.5 in. diameter variable flap ejector (VFE) nozzle, a round 'stovepipe' nozzle, and a 104 tube suppressor nozzle operated both with and without an ejector shroud. The velocities tested ranged from 600 to 1600 fps at an approximate total temperature of 1400 R. The axial position of the noise sources during static operation was determined by jet velocity, Strouhal number, and direction of propagation. The velocity dependence was more evident for the 104 tube suppressor nozzle than for the conical nozzles tested. The results for both the VFE conical nozzle and the stovepipe conical nozzle indicate source locations to be much closer to the jet exit plane than expected. Corrections for near field effects were found to differ slightly for each nozzle tested. The corrections presented are simply the differences between the measured near field levels and the required near field levels if spherical spreading is assumed from source to far field