Calculated performance map of a 4 1/2-stage 15.0 centimeter (5.9 inch) mean diameter turbine designed for a turbofan simulator
- Publication date
- Publisher
Abstract
The overall performance of an existing high-ratio turbine is calculated analytically over a range of speed and pressure ratio in order to determine its capability for other applications. The analytical performance covers a speed range from 50 to 120 percent of design and a pressure-ratio range from 5.0 to 35.0. The turbine was designed for a 50.8 centimeter (20.0 in.) tip diameter turbofan simulator. Computed results are compared with the experimental turbine data obtained from testing three fan configurations with the turbofan simulator in air. The comparison indicates good agreement over the range of speeds and pressure ratios covered by the experimental data