CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
research
Using a Conformal Water Bolus to Adjust Heating Patterns of Microwave Waveguide Applicators
Authors
Dewhirst
Drizdal
+8 more
Drizdal
Hasgall
Neufield
Rodrigues
Stauffer
Stauffer
Trefna
van Rhoon
Publication date
22 February 2017
Publisher
Jefferson Digital Commons
Doi
Abstract
Background: Hyperthermia, i.e., raising tissue temperature to 40-45°C for 60 min, has been demonstrated to increase the effectiveness of radiation and chemotherapy for cancer. Although multi-element conformal heat applicators are under development to provide more adjustable heating of contoured anatomy, to date the most often used applicator to heat superficial disease is the simple microwave waveguide. With only a single power input, the operator must be resourceful to adjust heat treatment to accommodate variable size and shape tumors spreading across contoured anatomy. Methods: We used multiphysics simulation software that couples electromagnetic, thermal and fluid dynamics physics to simulate heating patterns in superficial tumors from commercially available microwave waveguide applicators. Temperature distributions were calculated inside homogenous muscle and layered skin-fat-muscle-tumor-bone tissue loads for a typical range of applicator coupling configurations and size of waterbolus. Variable thickness waterbolus was simulated as necessary to accommodate contoured anatomy. Physical models of several treatment configurations were constructed for comparison of simulation results with experimental specific absorption rate (SAR) measurements in homogenous muscle phantom. Results: Accuracy of the simulation model was confirmed with experimental SAR measurements of three unique applicator setups. Simulations demonstrated the ability to generate a wide range of power deposition patterns with commercially available waveguide antennas by controllably varying size and thickness of the waterbolus layer. Conclusion: Heating characteristics of 915 MHz waveguide antennas can be varied over a wide range by controlled adjustment of microwave power, coupling configuration, and waterbolus lateral size and thickness. The uniformity of thermal dose delivered to superficial tumors can be improved by cyclic switching of waterbolus thickness during treatment to proactively shift heat peaks and nulls around under the aperture, thereby reducing patient pain while increasing minimum thermal dose by end of treatment. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE)
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Name not available
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:jdc.jefferson.edu:radoncfp...
Last time updated on 30/12/2017
Jefferson Digital Commons
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:jdc.jefferson.edu:radoncfp...
Last time updated on 15/06/2017
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1117%2F12.2252208
Last time updated on 05/06/2019