Žilinská univerzita v Žiline. Elektrotechnická fakulta
Abstract
This paper covers the circuit modification of the power part of the inverter with auxiliary resonant poles utilising
configuration of switches realised with routinely produced IGBT modules. Covered is also the control optimisation which
goal is the minimisation of switching of the auxiliary resonant pole. Presented results were gained on a prototype of an
inverter laboratory sample