Tracking Articulator Movements Using Orientation Measurements

Abstract

This paper introduces a new method to track articulator movements, specifically jaw position and angle, using 5 degree of freedom (5 DOF) orientation data. The approach uses a quaternion rotation method to accomplish this jaw tracking during speech using a single senor on the mandibular incisor. Data were collected using the NDI Wave Speech Research System for one pilot subject with various speech tasks. The degree of jaw rotation from the proposed approach is compared with traditional geometric calculation. Results show that the quaternion based method is able to describe jaw angle trajectory and gives more accurate and smooth estimation of jaw kinematics

    Similar works