OBJECTIVE: To assess the effects of 3 contrast medium injection techniques on attenuation values for canine adrenal glands during contrast-enhanced CT. ANIMALS 9 healthy Beagles.
PROCEDURES: 3 protocols were evaluated in a randomized cross-over design study: 700 mg of iodine/kg at a constant injection rate over 20 seconds (full-dose constant rate), the same dose at a rate following an exponential decay curve over 20 seconds (full-dose decelerated rate), and 350 mg of iodine/kg at a constant injection rate over 10 seconds (half-dose constant rate). Multislice CT images were obtained before and at predetermined time points after the start of contrast medium injection.
RESULTS: Median peak attenuation values were 129, 133, and 87 Hounsfield units with the full-dose constant rate, full-dose decelerated rate, and half-dose constant rate injection protocols, respectively. Peak attenuation differed significantly between the full-dose constant rate and half-dose constant rate injection protocols and between the full-dose decelerated rate and half-dose constant rate injection protocols. Median time to peak attenuation did not differ significantly among injection methods and was 30, 23, and 15 seconds for the full-dose constant rate, full-dose decelerated rate, and half-dose constant rate injections, respectively.
CONCLUSIONS AND CLINICAL RELEVANCE: The dose of contrast medium and the timing of postinjection CT scanning were main determinants of peak attenuation for adrenal glands in healthy dogs; effects of the 3 injection protocols on attenuation were minor. The exponentially decelerated injection method was subjectively complex. A constant injection protocol delivering 700 mg of iodine/kg over 20 seconds, with scans obtained approximately 30 seconds after starting contrast medium injection, provided images with maximum adrenal gland attenuation values