Abstract

Hyperoxia may induce pulmonary injury and may increase oxidative stress. In this retrospective database study we aimed to evaluate the response to hyperoxia by intensivists in a Dutch academic intensive care unit. All arterial blood gas (ABG) data from mechanically ventilated patients from 2005 until 2009 were extracted from an electronic storage database of a mixed 32-bed intensive care unit in a university hospital in Amsterdam. Mechanical ventilation settings at the time of the ABG tests were retrieved. The results of 126,778 ABG tests from 5,498 mechanically ventilated patients were retrieved including corresponding ventilator settings. In 28,222 (22%) of the ABG tests the arterial oxygen tension (PaO2) was > 16 kPa (120 mmHg). In only 25% of the tests with PaO2 > 16 kPa (120 mmHg) was the fraction of inspired oxygen (FiO(2)) decreased. Hyperoxia was accepted without adjustment in ventilator settings if FiO(2) was 0.4 or lower. Hyperoxia is frequently seen but in most cases does not lead to adjustment of ventilator settings if FiO(2) <0.41. Implementation of guidelines concerning oxygen therapy should be improved and further research is needed concerning the effects of frequently encountered hyperoxi