In this paper we describe how the readout planes for the MicroBooNE Time
Projection Chamber were constructed, assembled and installed. We present the
individual wire preparation using semi-automatic winding machines and the
assembly of wire carrier boards. The details of the wire installation on the
detector frame and the tensioning of the wires are given. A strict quality
assurance plan ensured the integrity of the readout planes. The different tests
performed at all stages of construction and installation provided crucial
information to achieve the successful realisation of the MicroBooNE wire
planes.Comment: 24 pages, 22 figures, accepted for publication as Technical Report in
JINS