Randomized Controlled Trial of the Clinical Recovery and Biodegradation of Polylactide-co-glycolide Implants Used in the Intramedullary Nailing of Children's Forearm Shaft Fractures with at Least Four Years of Follow-Up

Abstract

The preferred surgical fixation of forearm shaft fractures in children is Elastic Stable Intramedullary Nailing (ESIN). Due to known disadvantageous effects of metal implants, a new surgical method using biodegradable polylactide-co-glycolide (PLGA) intramedullary nails has been developed but its long-term outcomes are unclear. The aim of this study was to compare the long-term outcomes of Biodegradable Intramedullary Nailing (BIN) to ESIN and assess the biodegradation of the study implants via magnetic resonance imaging (MRI). The study population of the prospective, randomized trial consisted of paediatric patients whose forearm shaft fractures were treated with BIN (n = 19) or ESIN (n = 16). Forearm rotation at minimally four years' follow-up was the main outcome. There was no clinically significant difference in the recovery of the patients treated with the BIN as compared to those treated with the ESIN. More than half of the implants (57.7%, n = 15/26) were completely degraded, and the rest were degraded almost completely. The PLGA intramedullary nails used in the treatment of forearm shaft fractures in this study resulted in good function and anatomy. No unexpected disadvantages were found in the degradation of the implants. However, two implant failures had occurred in three months postoperatively.Peer reviewe