research

Smear layer removal in canals shaped with reciprocating rotary systems

Abstract

The aim was to assess the presence of smear layer after canal instrumentation with two reciprocating rotary systems and a continuous motion one. Thirty canals were shaped with Reciproc, WaveOne or Mtwo systems. Smear layer was assessed following a three value scale at coronal, middle and apical levels with a scanning electron microscopy. Reciproc scores: coronal third, 20% of the cases: 0, 60%: 1, 20%: 2; middle third, 10%: 0, 20%: 1, 70%:2; apical third: 2 in all cases. WaveOne scores: coronal third, 0 (40%), 1 (30%) and 2 (30%); middle third, 0 (20%), 1 (50%), 2 (30%); apical third, 0 (20%), 2 (80%) of cases. MTwo scores: coronal third 0 (50%), 1 (30%) 2 (20%); middle third 0 (20%), 1 (50%), 2 (30%); apical third, 0 (10%), 1 (10%), 2 (80%). No significant differences (p>0.05) were found between the three used systems