CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
research
Correlation of esophageal pressure-flow analysis findings with bolus transit patterns on videofluoroscopy
Authors
Charles Cock
Ian James Cook
+5 more
Julia C F Maclean
Jennifer C Myers
Taher Omari
Nathalie Rommel
Michal Marcin Szczesniak
Publication date
1 January 2016
Publisher
'Wiley'
Doi
Abstract
This is a pre-copyedited, author-produced version of an article accepted for publication in Diseases of the Esophagus following peer review. The version of record Omari TI, Szczesniak MM, Maclean J, Myers JC, Rommel N, Cock C and Cook IJ. Correlation of esophageal pressure-flow analysis findings with bolus transit patterns on videofluoroscopy. Dis Esophagus. 2016 Feb-Mar;29(2):166-73. and is available online at: http://dx.doi.org/10.1111/dote.12300 Copyright © 2017 The International Society for Diseases of the EsophagusPressure-flow analysis quantifies the interactions between bolus transport and pressure generation. We undertook a pilot study to assess the interrelationships between pressure-flow metrics and fluoroscopically determined bolus clearance and bolus transport across the esophagogastric junction (EGJ). We hypothesized that findings of abnormal pressure-flow metrics would correlate with impaired bolus clearance and reduced flow across the EGJ. Videofluoroscopic images, impedance, and pressure were recorded simultaneously in nine patients with dysphagia (62–82 years, seven male) tested with liquid barium boluses. A 3.6 mm diameter solid-state catheter with 25 × 1 cm pressure/12 × 2 cm impedance was utilized. Swallowed bolus clearance was assessed using a validated 7-point radiological bolus transport scale. The cumulative period of bolus flow across the EGJ was also fluoroscopically measured (EGJ flow time). Pressure only parameters included the length of breaks in the 20 mmHg iso-contour and the 4 second integrated EGJ relaxation pressure (IRP4s). Pressure-flow metrics were calculated for the distal esophagus, these were: time from nadir impedance to peak pressure (TNadImp to PeakP) to quantify bolus flow timing; pressure flow index (PFI) to integrate bolus pressurization and flow timing; and impedance ratio (IR) to assess bolus clearance. When compared with controls, patients had longer peristaltic breaks, higher IRs, and higher residual EGJ relaxation pressures (break length of 8 [2, 13] vs. 2 [0, 2] cm, P = 0.027; IR 0.5 ± 0.1 vs. 0.3 ± 0.0, P = 0.019; IRP4s 11 ± 2 vs. 6 ± 1 mmHg, P = 0.070). There was a significant positive correlation between higher bolus transport scores and longer peristaltic breaks (Spearman correlation r = 0.895, P < 0.001) and with higher IRs (r = 0.661, P < 0.05). Diminished EGJ flow times correlated with a shorter TNadImp to PeakP (r = −0.733, P < 0.05) and a higher IR (r = −0.750, P < 0.05). Longer peristaltic breaks and higher IR correlate with failed bolus clearance on videofluoroscopy. The metric TNadImp to PeakP appears to be a marker of the period of time over which the bolus flows across the EGJ
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1111%2Fdote.12300
Last time updated on 04/12/2019
Adelaide Research & Scholarship
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:digital.library.adelaide.e...
Last time updated on 08/03/2017
Flinders Academic Commons
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:dspace.flinders.edu.au:232...
Last time updated on 30/04/2017