Prevention of Post-Endoscopic Retrograde Cholangiopancreatography Pancreatitis by Endoscopic Pancreatic Stenting after Insertion of Self-Expandable Metal Stent for Malignant Distal Biliary Stricture

Abstract

The insertion of a self-expandable metal stent (SEMS) for nonpancreatic cancer is a factor predicting the risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP). We evaluated the efficacy of endo-scopic pancreatic stenting (EPS) to prevent PEP after SEMS insertion in patients with malignant distal biliary stricture and without main pancreatic duct (MPD) obstruction. We performed a single-center, retrospective, historically controlled investigation to assess the outcomes of 33 consecutive patients who underwent SEMS insertion. From March 2013 to June 2015, 13 patients did not undergo EPS (Non-EPS group). The other 20 patients underwent EPS (EPS group) between July 2015 and August 2018. The background data demonstrated no significant differences. Except for one patient in the Non-EPS group, all patients underwent biliary sphinc-terotomy. The EPS group’s PEP incidence was significantly lower (n = 1, 5%) than that of the Non-EPS group (n = 4, 31%) (p = 0.04). The median serum amylase and lipase levels after the procedure were significantly lower in the EPS group than in the Non-EPS group (amylase: 104 vs. 262 U/L; p < 0.01, lipase: 102 vs. 666 U/L; p = 0.01). The use of EPS decreased the incidence of PEP after SEMS insertion in individuals with malignant distal biliary stricture and without MPD obstruction