It was found the corrosion-mechanical signs of degradation the power components of
the Shukhov’s tower, resulting from its long-term operation for combined influence of loads
and atmospheric environment. The fibration of metal at the ends of the structural units
associated with the wedging-effect of corrosion products, surface corrosion damages and
stress corrosion cracking of welded joints between old and repair metals were revealed