Аналіз ознак деградації тривало експлуатованих елементів веж Шухова

Abstract

It was found the corrosion-mechanical signs of degradation the power components of the Shukhov’s tower, resulting from its long-term operation for combined influence of loads and atmospheric environment. The fibration of metal at the ends of the structural units associated with the wedging-effect of corrosion products, surface corrosion damages and stress corrosion cracking of welded joints between old and repair metals were revealed