research

EFFECTIVE SEDIMENT CONTROL IN A RESERVOIR

Abstract

Sedimentation in a reservoir cannot be avoided. The average rate of sedimentation on the storage volume reduction of a reservoir in the world is about 1 % per year (Yoon,1992), meanwhile, the storage volume reduction in several reservoir in Indonesia reaches 1,64% to 2,83% per year (Atmojo,2012). These sediment’s accumulations in the reservoir will continually reduce the storage volume, thus the intended functions of reservoirs for flood control (Atmojo, 2013), irrigation and water supply, electric generation, etc. will also reduced and not optimal. Some of sediment control measures have been practiced in reducing sediment accumulation in reservoirs around the world. In principle, there are two approaches i.e., reduce the sediment input to a reservoir by land conservation, construction of check dam, sand pocket, diversion channel, etc. and reduce the sedimentation in the reservoir by sluicing, turbidity current, dredging, and flushing (Morris and Fan, 1998; Emamgholizadeh et al., 2006). This paper presents the performance of sediment’s reduction from a reservoir by flushing, sluicing, and disturbing flushing based on some laboratories results (Atmojo,2012). It is expected that this paper can contribute to elicits some finding on the selection of which suitable method for sediment reduction from a reservoir

    Similar works