Experiments investigating concrete floor punching using specific reinforcement

Abstract

To reduce the surface crack width and to optimize the ultimate punching load of warehouse concrete floors, fibre reinforcement and special reinforcement mats above piles are used. Due to the special reinforcement mats, current design rules cannot be used to correctly predict the surface crack width and the ultimate punching load. Therefore, full-scale experiments have been carried out for six different reinforcement types. A fibre-reinforced floor with circular pile mat is the best solution, both for reducing the surface crack width and for optimizing the ultimate punching load

    Similar works