Blood cyanide determination in two cases of fatal imtoxication: comparison between headspace gas chromatography and a spectrophotometric method

Abstract

Blood samples of two cases were analyzed preliminarily by a classical spectrophotometric method (VIS) and by an automated headspace gas chromatographic method with nitrogen-phosphorus detector (HS-GC \u2044 NPD). In the former, hydrogen cyanide (HCN) was quantitatively determined by measuring the absorbance of chromophores forming as a result of interaction with chloramine T. In the automated HS-GC \u2044NPD method, blood was placed in a headspace vial, internal standard (acetonitrile) and acetic acid were then added. This resulted in cyanide being liberated as HCN. The spectrophotometric (VIS) and HS-GC\u2044NPD methods were validated on postmortem blood samples fortified with potassium cyanide in the ranges 0.5\u201310 and 0.05\u20135 lg \u2044 mL, respectively. Detection limits were 0.2 lg \u2044mL for VIS and 0.05 lg \u2044mL for HS-GC\u2044NPD. This work shows that results obtained by means of the two procedures were insignificantly different and that they compared favorably. They are suitable for rapid diagnosis of cyanide in postmortem cases