In-vivo diffusing-wave-spectroscopy measurements of the ocular fundus

Abstract

We present what is to our knowledge the first observation of a diffusing-wave-spectroscopy signal recorded in-vivo on the ocular fundus. A modified ophthalmic microscope was developed which can acquire diffusing-wave-spectroscopy signal from the eye fundus. The diffusing-wave-spectroscopy signal was recorded in-vivo on a rabbit eye during transpupillary thermotherapy. Experimental results show the ability of the system to detect motion of the scattering sites in the ocular fundus layers during laser thermal heating. (c) 2007 Optical Society of America