Synthesis and study of kinetic parameters of nanophosphor LiB3O5: Al
Authors
A. Abdisaray
Parvin Kaviani
J. Khorsandi
Daryoush Shahbazi-Gahrouei
Publication date
1 January 2019
Publisher
Doi
Cite
Abstract
Background: Thermoluminescence dosimeters are the most widely used inactive in vivo dosimeters. Nanoparticles have more suitable dosimetry properties than similar bulk materials. The purpose of this study was to synthesize and to determine the kinetic parameters of nanophosphor equivalent to human tissue for using in medical purposes. Methods: After synthesis of LiB3O5 nanophosphor, structure and its dimensions were investigated using X-ray diffraction pattern (XRD) and scanning electron microscopy (SEM). Different activators were added to each nanophosphor with 0.5, 1, and 2 percent of weight, to select the most suitable compound as a usable thermoluminescence dosimeter in medicine. The kinetic parameters of the glow peaks were calculated using four methods, and the results of these methods were compared. Findings: SEM and XRD analysis showed that the dimensions of synthesized phosphorus were less than 100 nm, and had a relatively high purity. By irradiating and reading the samples, the best peak position and intensity of the glow curve were obtained by 2 percent of weight aluminum (Al) activator at the peak temperature of 183 °C. Conclusion: The results of different methods were in good agreement. The calculated mean value of the activation energy was 1.243 eV, which had a good energy level for the thermoluminescent dosimeter (TLD) reader. By comparing the experimental and computational values, the validity of the computational methods was confirmed. © 2019, Isfahan University of Medical Sciences(IUMS). All rights reserved
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Repository of Research and Investigative Information Isfahan University of Medical Sciences
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:eprints.mui.ac.ir:11901
Last time updated on 13/07/2025