The Mechanical Design Of The Bpm Inter-Tank Section For P-Linac At FAIR

Abstract

At the planned Proton LINAC at the FAIR facility,four-fold button Beam Position Monitor (BPM) will beinstalled at 14 locations along the 30 m long FAIR p-LINAC. The LINAC comprises of crossbar H-mode (CH)cavity to accelerate a 70 mA proton beam up to 70 MeVat frequency of 325 MHz. At four locations, the BPMswill be an integral part of the inter-tank section betweenthe CCH and CH cavities within an evacuated housing.As the BPM centre is only 48 mm apart from the upstreamcavity boundary, the rf-background at the BPMposition, generated by the cavity must be evaluated. Inthis paper the mechanical design of the BPM for the intertanksection is presented and the rf-noise at the BPMlocation is discussed