E.Lundberg等人在用石墨炉原子吸收法测锡的影响因素中指出,由于锡有生成挥发性化合物和与石墨互相作用的倾向,因此锡是用石墨炉测定最麻烦的元素之一.W.B.Barnett等人用石墨炉原子吸收法测定了铜和锌合金中六个元素,其中锌合金中锡是用标准加入法,而测黄铜中锡,无论用合成标准法还是用标准加入法都未成功.本文用涂钨热解管,提高了灰化温度,同是采用抗坏血酸作干扰抑制剂,消除了锌基体及共存元素的干扰,用标准曲线法直接测定锌合金中微量锡,获得了满意结果.实验表明,抗坏血酸不能抑制铜对锡的干扰,但采用标准加入法测定铜合金中锡,结果与标准值吻合.本方法的灵敏度为14pg/1%吸收,检测限为4pg(4.0×10~(-12)g)