Optimizing gamma-ray spectrometers for UAV-borne surveys with geophysical applications

Abstract

Heavy duty unmanned aerial vehicles (UAVs) have made it possible to fly with large gamma-ray spectrometers that weigh several kilograms. Moreover, they can be purchased at an affordable price. These large UAV-borne gamma-ray detection systems are used to map the naturally occurring radionuclides 40K, 238U, 232Th. Such platforms have the advantage that they can be deployed over terrain that is difficult to access, while still maintaining a high spatial resolution. In contrast to UAV-borne radioactive pollution studies, the naturally occurring radionuclides have a much lower activity and therefore require longer integration time, slower flying speed or a larger detector, in order to effectively determine the spatial radionuclide distribution. Therefore, the question arises: what is the minimum practical detector size required to successfully map 40K, 238U and 232Th concentrations from UAV platforms. In this study an agricultural field has been mapped with three different scintillator-based gamma-ray spec-trometers: a 2000 ml, 1000 ml, and 350 ml detector. They were mounted together on the same UAV. At a flying height of 20 m and a speed of 5.6 m

    Similar works

    Available Versions

    Last time updated on 02/01/2023