Transient capacitance measurements of deep level defects introduced in y-ray compensated germanium by long-term annealing at room temperature.

Abstract

Deep level transient spectroscopy (DLTS) has been applied to defect centres in γ-ray compensated germanium that has been subjected to long-term annealing at room temperature. Deep donor levels (Ec - 0.36 eV Ec - 0.20 eV) have been observed for the first time; annealing at 675ºC for 3 hours increased their concentration in proportion to the free carrier density indicating stable defect-impurity complexes. Recently irradiated samples from the original material have not shown these levels. The results support Russian work on the compensation mechanism - the formation of electically inactive vacancy-donor complexes