research

Effects of increased leading-edge thickness on performance of a transonic rotor blade

Abstract

A single-stage transonic compressor was tested with two rotor blade leading-edge configurations to investigate the effect of increased leading-edge thickness on the performance of a transonic blade row. The original rotor blade configuration was modified by cutting back the leading edge sufficiently to double the blade leading-edge thickness and thus the blade gap blockage in the tip region. At design speed this modification resulted in a decrease in rotor overall peak efficiency of four points. The major portion of this decrement in rotor overall peak efficienty was attributed to the flow conditions in the outer 30 percent of the blade span. At 70 and 90 percent of design speed, the modification had very little effect on rotor overall performance

    Similar works