research

Experimental transient vane temperatures in a cascade for gas stream temperature cycling between 922 and 1644 K (1200 and 2500 F)

Abstract

Experimental transient turbine vane metal temperatures were obtained from tests conducted on air-cooled vanes installed in a four-vane cascade for a gas temperature cycled between 922 and 1644 K (1200 and 2500 F). Transient data were recorded by a high-speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 11 kelvins (20 F), simulated cruise and idle steady-state readings were repeated by the cruise and idle readings taken from the ends of a transient half-cycle at low pressure to within 17 kelvins (30 F). The tests were conducted at pressure levels of 31 and 83 N-sq cm (45 and 120 psia) with coolant temperatures of 811 and 589 K (1000 and 600 F), respectively

    Similar works