External tank gaseous oxygen line simulated lightning tests

Abstract

Tests were made to evaluate the effects of lightning strikes on the shuttle external tank gaseous oxygen pressurization line. This line, designed to conduct gaseous oxygen may also act as a lightning conductor. Questions have been raised as to the potential hazard of this line as a lightning conductor with speculation as to the damage that might occur to the pressurization line, and the adjacent thermal protective surfaces, from a lightning strike. The region of investigation was from above the cone of the launch tower lightning protection to 15.24 km (50, 000 ft) altitude. Tests were performed on samples of thin wall stainless steel tubing filled with gaseous oxygen under simulated flight conditions. No specimen malfunctions occurred when the tests were conducted according to JSC specifications. Based on the JSC specifications and the results of these tests, it is concluded that a lightning strike will not cause a malfunction of the shuttle external tank gaseous oxygen line made of the representative material tested